Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 30(24): 43888-43899, 2022 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-36523077

RESUMO

Optical enhancement cavities enabling laser pulses to be coherently stacked in free space are used in several applications to enhance accessible optical power. In this study, we develop an optical cavity that accumulates harmonically mode-locked laser pulses with a self-resonating mechanism for X-ray sources based on laser-Compton scattering. In particular, a Fabry-Perot cavity composed of 99% reflectance mirrors maintained the optical resonance in a feedback-free fashion for more than half an hour and automatically resumed the accumulation even if the laser oscillation was suspended. In contrast to conventional optical enhancement cavity systems with a dedicated feedback controller, this characteristic is highly beneficial in practical applications, such as for laser-Compton scattering X-ray sources. Lastly, upscaling and adoption of the proposed system might improve the operability and equipment use of laser Compton-scattering X-ray sources.

2.
Rev Sci Instrum ; 89(2): 023305, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29495841

RESUMO

We describe the stabilization technique of an optical enhancement cavity using a counter propagating mode. The burst amplification of the injection laser in the main path induces a drastic change in the laser intensity and disturbs the stabilization of the enhancement cavity. We have used a counter propagating mode to achieve a 4% intensity jitter and 0.6 mJ pulse storage inside the cavity at the maximum of the burst region. Our results indicate that the counter propagating mode has the same resonant condition as the main mode and thus becomes useful for stabilizing the enhancement cavity. We also determined that the burst amplification brought about no decrease in the enhancement factor in the cavity due to the degradation of laser quality.

3.
Phys Rev Lett ; 107(17): 174801, 2011 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-22107525

RESUMO

We represent the first experimental observation of the point spread function (PSF) of optical transition radiation (OTR) performed at KEK-Accelerator Test Facility extraction line. We have demonstrated that the PSF vertical polarization component has a central minimum with a two lobe distribution. However, the distribution width varied significantly with wavelength. We assume that we observed a severe effect from spherical or chromatic aberrations which are not taken into account in any existing theoretical model. We believe that the result of this work will encourage theoreticians to continue developing the theory as it is important for various transition radiation applications. Nonuniform distribution of the OTR PSF creates an opportunity for developing a submicrometer transverse beam size monitor.

4.
Rev Sci Instrum ; 80(12): 123304, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20059137

RESUMO

X-ray generation based on laser-electron Compton scattering is one attractive method to achieve a compact laboratory-sized high-brightness x-ray source. We have designed, built, and tested such a source; it combines a 50 MeV multibunch electron linac with a mode-locked 1064 nm laser stored and amplified in a Fabry-Perot optical cavity. We directly observed trains of pulsed x rays using a microchannel plate detector; the resultant yield was found to be 1.2x10(5) Hz in good agreement with prediction. We believe that the result has demonstrated good feasibility of linac-based compact x-ray sources via laser-electron Compton scatterings.

5.
Phys Rev Lett ; 93(24): 244802, 2004 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-15697821

RESUMO

An experiment on the investigation of optical diffraction radiation (ODR) from a slit target as a possible tool for noninvasive electron beam-size diagnostics has been performed at the KEK accelerator test facility. The experimental setup has been installed at the diagnostics section of the extraction line. We have performed the first incoherent ODR observation from a slit target. The measured angular distributions are in reasonable agreement with the theoretical expectation. The beam-size effect onto the ODR angular pattern has been observed. Moreover, the sensitivity to the beam size as small as 14 microm has been achieved.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...